Qwik Fixings

Qwik Fix Masonry Support Systems

Spandrel & Parapet Posts

Spandrel & Parapet Posts


Maximum Unfactored Wind Load [kN] for Height [mm] of U-Type Spandrel/Parapet Post UDL

Windpost loadings are derived from an allowable stress value of 181N/mm² and a deflection limit of Span ÷ 360. The lesser of the two figures is the quoted loading.

Code

Size (mm)

800

1000

1200

1400

1600

1800

2000

U1

60 x 60 x 4

6.0

3.9

2.7

2.0

1.5

 

 

U2

60 x 60 x 4

7.2

4.6

3.2

2.4

1.8

 

 

U3

60 x 60 x 5

8.8

7.0

5.0

3.7

2.8

 

 

U4

75 x 60 x 4

8.5

6.4

4.5

3.3

2.5

 

 

U5

75 x 60 x 5

9.3

7.5

5.4

3.9

3.0

 

 

U6

75 x 60 x 6

9.3

7.5

6.2

4.6

3.5

 

 

U7

115 x 60 x 4

9.3

7.5

6.2

5.3

4.6

 

 

U8

115 x 60 x 5

9.3

7.5

6.2

5.3

4.6

 

 

U9

115 x 60 x 6

9.3

7.5

6.2

5.3

4.6

 

 

 

U Spandrel Windpost