LP Windposts

 

Maximum Unfactored Wind Load [kN] for Height [mm] of LP-Type Windpost UDL

Windpost loadings are derived from an allowable stress value of 181N/mm² and a deflection limit of Span ÷ 360. The lesser of the two figures is the quoted loading.

Code

Size (mm)

2500

3000

3500

4000

4500

5000

5500

6000

LP1

125 x 70 x 4

9.0

6.2

4.6

3.5

 

 

 

 

LP2

125 x 70 x 5

11.0

7.7

5.7

4.3

3.4

 

 

 

LP3

125 x 70 x 6

13.1

9.1

6.7

5.1

4.1

3.3

 

 

LP4

150 x 70 x 4

12.5

10.2

7.5

5.7

4.5

3.7

3.0

 

LP5

150 x 70 x 5

15.5

12.6

9.3

7.1

5.6

4.5

3.8

3.2

LP6

150 x 70 x 6

18.5

15.0

11.0

8.4

6.7

5.4

4.5

3.7

LP7

170 x 70 x 4

15.8

13.1

10.5

8.1

6.4

5.2

4.3

3.6

LP8

170 x 70 x 5

19.0

16.3

13.0

10.0

7.9

6.4

5.3

4.4

LP9

170 x 70 x 6

19.0

19.0

15.5

11.8

9.4

7.6

6.3

5.3

LP10

200 x 70 x 4

19.0

17.8

16.3

12.5

9.9

8.0

6.6

5.6

LP11

200 x 70 x 5

19.0

19.0

18.9

15.5

12.2

9.9

8.2

6.9

LP12

200 x 70 x 6

19.0

19.0

19.0

18.4

14.5

11.8

9.7

8.2

 