U Windposts
Maximum Unfactored Wind Load [kN] for Height [mm] of Type U Windpost UDL
Windpost loadings are derived from an allowable stress value of 181N/mm² and a deflection limit of Span ÷ 360. The lesser of the two figures is the quoted loading.
|
Code |
Size (mm) |
2500 |
3000 |
3500 |
4000 |
4500 |
5000 |
5500 |
6000 |
|
U1 |
60 x 60 x 4 |
3.0 |
2.1 |
|
|
|
|
|
|
|
U2 |
60 x 60 x 5 |
3.5 |
2.5 |
1.8 |
|
|
|
|
|
|
U3 |
60 x 60 x 6 |
5.5 |
3.8 |
2.8 |
2.2 |
|
|
|
|
|
U4 |
75 x 60 x 4 |
4.9 |
3.4 |
2.5 |
1.9 |
|
|
|
|
|
U5 |
75 x 60 x 5 |
5.9 |
4.1 |
3.0 |
2.3 |
1.8 |
|
|
|
|
U6 |
75 x 60 x 6 |
6.9 |
4.8 |
3.5 |
2.7 |
2.1 |
|
|
|
|
U7 |
115 x 60 x 4 |
13.2 |
9.2 |
6.7 |
5.2 |
4.1 |
3.3 |
|
|
|
U8 |
115 x 60 x 5 |
16.1 |
11.2 |
8.2 |
6.3 |
5.0 |
4.0 |
3.3 |
|
|
U9 |
115 x 60 x 6 |
18.8 |
13.0 |
9.6 |
7.3 |
5.8 |
4.7 |
3.9 |
3.3 |