Maximum Unfactored Wind Load [kN] for Height [mm] of U-Type Spandrel/Parapet Post UDL

Windpost loadings are derived from an allowable stress value of 181N/mm² and a deflection limit of Span ÷ 360. The lesser of the two figures is the quoted loading.

Code

Size (mm)

800

1000

1200

1400

1600

1800

2000

U1

60 x 60 x 4

6.0

3.9

2.7

2.0

1.5

 

 

U2

60 x 60 x 4

7.2

4.6

3.2

2.4

1.8

 

 

U3

60 x 60 x 5

8.8

7.0

5.0

3.7

2.8

 

 

U4

75 x 60 x 4

8.5

6.4

4.5

3.3

2.5

 

 

U5

75 x 60 x 5

9.3

7.5

5.4

3.9

3.0

 

 

U6

75 x 60 x 6

9.3

7.5

6.2

4.6

3.5

 

 

U7

115 x 60 x 4

9.3

7.5

6.2

5.3

4.6

 

 

U8

115 x 60 x 5

9.3

7.5

6.2

5.3

4.6

 

 

U9

115 x 60 x 6

9.3

7.5

6.2

5.3

4.6

 

 

Maximum Unfactored Wind Load [kN] for Height [mm] of LP-Type Spandrel/Parapet Post UDL

Code

Size

800

1000

1200

1400

1600

1800

2000

LP1

125 x 70 x 4

7.0

5.6

4.6

4.0

3.5

3.1

2.8

LP2

125 x 70 x 5

8.0

6.9

5.8

4.9

4.3

3.8

3.5

LP3

125 x 70 x 6

8.0

8.0

6.8

5.9

5.1

4.6

4.1

LP4

150 x 70 x 4

8.0

7.8

6.5

5.6

4.9

4.3

3.9

LP5

150 x 70 x 5

8.0

8.0

8.0

8.0

6.1

5.4

4.9

LP6

150 x 70 x 6

8.0

8.0

8.0

8.0

7.2

6.4

5.8

LP7

170 x 70 x 4

8.0

8.0

8.0

7.0

6.2

5.5

4.9

LP8

170 x 70 x 5

8.0

8.0

8.0

8.0

7.7

6.8

6.1

LP9

170 x 70 x 6

8.0

8.0

8.0

8.0

8.0

8.0

7.3

LP10

200 x 70 x 4

8.0

8.0

8.0

8.0

8.0

7.4

6.7

LP11

200 x 70 x 5

8.0

8.0

8.0

8.0

8.0

8.0

8.0

LP12

200 x 70 x 6

8.0

8.0

8.0

8.0

8.0

8.0

8.0

© 2010 Coughlan Engineering (Tullamore) Ltd t/a Qwik Fixings
Registered in Ireland # 281833
Riverside, Tullamore,
County Offaly, Republic of Ireland
Qwik Fix provides Masonry Fixings and Construction Accessories to the construction markets in Ireland, the United Kingdon, the United States and Canada. Our fixings are intelligently designed with the aim of saving you money. We achieve this by using advanced materials such as duplex stainless steel and polymer composites where appropriate and beneficial. We design our products to contribute to rapid construction techniques and to negate sources of thermal bridging. Our masonry fixings and construction accessories are used in double leaf rainscreen veneer wall construction, and are suitable for use in concrete, steel and timber frame buildings.