Qwik Fixings

Qwik Fix Masonry Support Systems

Fixings For Concrete

Masonry Support - Fixings for Concrete

Cast-in Channel:

Fixing to a cast-in stainless steel channel can speed up installation of Qwik-Fix™ Angle considerably because it negates the need for on site drilling.

Anchoring Depth from Concrete Face (h)

Design Tensile Load Capacity (kN)

7.0 per fixing

Design Shear Load Capacity (kN)

8.0 per fixing

Minimum Fixing Centres (mm)*

300

Minimum Edge Distance (mm)*

75

Minimum Corner Distance (mm)*

50

Minimum Spacing (mm)*

100

Channel Width (mm)

38

Channel Gauge (mm)

3

Channel Opening (mm)

18

Anchoring Depth from Concrete Face (h)

50mm

Material

A2 Stainless

Fixing Bolt

M12

* Loads shown are based on non-cracked concrete C20/25 without axial spacing and edge influences. Where factors apply please contact the Qwik-Fix technical department for guidance

 

Channel Assembly

 

Mechanical Expansion Bolts

Design Tensile Load (kN)

13.9

10.7

Design Shear Load (kN)

17.5

23.6

Minimum Edge Distance (mm)*

75

55

Minimum Spacing (mm)*

80

50

Maximum Fixing Thickness (mm)

45

20

Material

A4 Stainless

A4 Stainless

Design Method

ETAG 001 Annex C

ETAG 001 Annex C

European Technical Approval No.

02/0037

01/0015

* Loads shown are based on C20/25 concrete without axial spacing and edge influences. Where factors apply please contact the Qwik-Fix technical department for guidance.

 

Chemical Anchors

  RG M12 x 160 A4
Standard Anchor for Use in Uncracked Concrete
FHB II-A S A4 M 12 x 75/25
High Performance Anchor for Use in Cracked Concrete
Design Tensile Load (kN) 17.2 15.6
Design Shear Load (kN) 18.9 29.9
Minimum Edge Distance (mm)* 55 40
Minimum Spacing (mm)* 55 40
Maximum Fixing Thickness (mm) 25 25
Curing Time @ Temp. (mins)

-5˚C  –  0˚C

1˚C  – 10˚C

10˚C  – 20˚C

≥20˚C

 

240

45

20

10

 

8

6

4

2

Design Method TR29 for bonded anchors ETAG 001 Annex C
European Technical Approval No. 08/0010 05/164

* Loads shown are based on C20/25 concrete without axial spacing and edge influences. Where factors apply please contact the Qwik-Fix technical department for guidance